Phase Converter Sizing Guide

Select your machine type and its horsepower or amperage rating to find the recommended NAPCco phase converter. Easy-starting motors require modest oversizing, while lathes, compressors, pumps, and CNC machines can require substantially more starting capacity.

Need help with phase converter sizing? Talk to an Application Engineer!

Need help with phase converter sizing? Talk to an Application Engineer!

Rotary Phase Converter Sizing Formulas

The sizing multiplier used is based on load type, and a machine’s load type is determined by its startup characteristics. Some machines are easy to get up to speed, while others draw higher amounts of current to get started. We use the multipliers below as a general rule of thumb. If you are in between converter sizes, round up.

Easy Loads:
1.25x HP or FLA

Table Saw, Drill Press

Medium Loads:
1.5x HP or FLA

Mill, Grinder

Hard Loads:
2x HP or FLA

Lathe, Jointer, Planer

Very Hard Loads:
2.5x HP or FLA

Air Compressor, Vacuum Pump

CNC/Resistive:
2x HP or FLA

CNC Machine, Welder

Rotary Sizing Examples

Load Type Machine Math Rotary Phase Converter Size
Easy 3 HP Table Saw 3 HP x 1.25 = 3.75 HP 5 HP – rounded up to nearest size
Medium 5 HP Mixer 5 HP x 1.5 = 7.5 HP 7.5 HP
Hard 10 HP Gearhead Lathe 10 HP x 2 = 20 HP 20 HP
Very-Hard 7.5 HP Piston Air Compressor 7.5 HP x 2.5 = 18.75 HP 20 HP – rounded up to nearest size
Very-Hard – Smart-Boost™ 7.5 HP Piston Air Compressor 7.5 HP x 2 = 15 HP 15 HP*
CNC/Resistive 70 FLA CNC Mill 70 FLA x 2 = 140 FLA 60 HP*

*Smart-Boost™ converters have a digital controller that delivers extra current during startup, so you can use a multiplier of 2 instead of 2.5 for very-hard loads.
*The PL-60 has a maximum output of 144 A. To cover startup demand, we recommend it for three-phase loads up to 72 FLA.

Digital Phase Converter Sizing Formulas

For most applications, you can match the digital phase converter’s HP or amp rating to your machine’s HP or amp rating. We recommend going one size up for very hard loads, like air compressors. 

Easy / Medium / Hard Loads:
Match HP or FLA 

Very Hard Loads:
Next Size Up

CNC/Resistive:
Match HP or FLA 

Digital Sizing Examples

Load Type Machine Digital Phase Converter Size
Easy 5 HP Drill Press 5 HP
Medium 10 HP Grinder 10 HP
Hard 20 HP Wide Belt Sander 20 HP
Very Hard 25 HP Elevator 30 HP (one size up)
CNC/Resistive 50 FLA CNC Mill 15 HP*

*The TPX-52e is a 15 HP digital phase converter with a maximum three-phase output of 52 A.

Sizing a Rotary Phase Converter for Multiple Machines 

One rotary phase converter can power a whole shop if sized correctly. Follow the steps below to find the size you need:

Step 1: Add together the HP or FLA of all machines that will be running at the same time.

Step 2: Identify which of those machines requires the highest sizing multiplier.

Step 3: Multiply the total HP or FLA from Step 1 by the highest multiplier identified in Step 2.

Step 4: If the result falls between two converter sizes, round up to the next available size.

Sizing Example

Woodworking shop with 5 HP shaper, 5 HP jointer, and 7.5 HP dust collector.

  • Step 1: 5 HP + 5 HP + 7.5 HP = 17.5 HP
  • Step 2: Both the jointer and the dust collector are hard-starting loads, so we use a multiplier of 2.
  • Step 3: 17.5 x 2 = 35 HP
  • Step 4: Round up to the closest size, which would be a 40 HP Phase Converter

Sizing Tables

Use the load type chart below to determine the load type of your machine: easy, medium, hard, very hard, CNC, inductive, or resistive. Then use the sizing table to determine which size phase converter you need. The video walks you through how to use the tables.

Sizing Chart For Pro-Line Rotary Phase Converters

Phase Converter Model (HP) Motor Loads (Horsepower) CNC, Resistive & Inductive Loads Shop
Easy Med Hard Very Hard Total Amps Total kVA Total kW Spindle HP
PL-3 2 2 1.5 1 4 1.4 1.1 1.5 Shop PL-3
PL-5 3 3 2.5 1.5 7 2.4 1.7 2.5 Shop PL-5
PL-7 5 5 3 2.5 11 5 2.2 3 Shop PL-7
PL-10 7.5 6 5 3 15 6 3.7 5 Shop PL-10
PL-15 10 7.5 7.5 5 20 8 5.6 7.5 Shop PL-15
PL-20 15 12.5 10 7.5 25 11 7.7 10 Shop PL-20
PL-25 20 15 12.5 10 30 15 9.5 12 Shop PL-25
PL-30 25 20 15 10 37 20 11.8 15 Shop PL-30
PL-40 30 25 20 15 50 25 15.5 20 Shop PL-40
PL-50 40 30 25 20 61 30 21.5 25 Shop PL-50
PL-60 50 40 30 25 72 36 26.5 30 Shop PL-60
PL-80 60 50 40 30 100 42 29.6 40 Shop PL-80
PL-100 75 60 50 40 122 48 37.3 50 Shop PL-100

Sizing Chart for Smart-Boost™ Rotary Phase Converters

Smart-Boost™ Rotary Converter Model Motor Loads (Horsepower) CNC, Resistive & Inductive Loads Shop
Easy Med Hard Very Hard Total Amps Total kVA Total kW Spindle HP
SB-3 2 2 1.5 1.5 4 1.6 1.1 1.5 Shop SB-3
SB-5 3 3 2.5 2.5 7 2.9 1.7 2.5 Shop SB-5
SB-7 5 5 3 3 11 4.5 2.2 3 Shop SB-7
SB-10 7.5 6 5 5 15 6 3.7 5 Shop SB-10
SB-15 10 10 7.5 7.5 20 8 5.6 7.5 Shop SB-15
SB-20 15 12.5 10 10 25 11 7.7 10 Shop SB-20
SB-25 20 15 12.5 12.5 30 13 9.5 12.5 Shop SB-25
SB-30 25 20 15 15 37 15 11.8 15 Shop SB-30
SB-40 30 25 20 20 50 21 15.5 20 Shop SB-40
SB-50 40 30 25 25 62 25 21.5 25 Shop SB-50
SB-60 50 40 30 30 72 30 26.5 30 Shop SB-60

Sizing Chart for TritonPro Maxx™ Digital Phase Converters

Digital Phase Converter Model Motor Loads (Horsepower) CNC, Resistive & Inductive Loads Shop
Easy Med Hard Very Hard Total Amps Total kVA Total kW Spindle HP
TPX-18e 5 5 5 2.5 18 1.6 1.1 5 Shop TPX-18e
TPX-26e 7.5 7.5 7.5 5 26 2.9 1.7 7.5 Shop TPX-26e
TPX-36e 10 10 10 7.5 36 4.5 2.2 10 Shop TPX-36e
TPX-52e 15 15 15 10 52 6 3.7 15 Shop TPX-52e
TPX-64e 20 20 20 15 64 8 5.6 20 Shop TPX-64e
TPX-79e 25 25 25 20 79 11 7.7 25 Shop TPX-79e
TPX-95 30 30 30 25 95 13 9.5 30 Shop TPX-95
TPX-130 40 40 40 30 130 15 11.8 40 Shop TPX-130
TPX-165 50 50 50 40 165 21 15.5 50 Shop TPX-165
TPX-190 60 60 60 50 190 25 21.5 60 Shop TPX-190
TPX-240 75 75 75 60 240 30 26.5 75 Shop TPX-240

Phase Converter Sizing FAQs

Yes, as long as the phase converter is sized correctly, it can run multiple machines at the same time. The phase converter feeds into a three-phase load center, and each machine wires into its own circuit breaker. This is often easier and more cost effective than supplying each machine with its own converter or VFD.

No, a rotary phase converter does not change the input voltage. If your utility supply is 240 V single-phase, the phase converter will provide 240 V three-phase. For equipment that needs a different output voltage, a transformer is installed after the phase converter. This device takes the power output of the phase converter and steps the voltage up or down. 

Once the sizing calculator recommends a phase converter, there will be an option to input your supply voltage and machine’s voltage. If they differ, the calculator will provide a recommended transformer size rated in kVA.

Yes, a rotary phase converter can be too small. It has to supply the running amps and also handle the inrush current your equipment draws at startup. If it can’t, the load will struggle to start, overheat, or trip breakers. You can also damage your equipment. 

Whether a rotary phase converter can be too large depends on the manufacturer. NAPCco phase converters can be oversized, and choosing a converter with extra capacity can be helpful later on. A larger converter produces a stiffer, stronger generated leg. Because a phase converter is a pass-through device, it only draws the power your three-phase load needs.

How much extra capacity you add depends on your budget and any plans to expand your shop in the future.

Please call us at 877-545-2926 or use our contact form

If you have any questions about our products, features or sizing